M8 limit switches

Technical data :

General
StandardsIEC/EN 60947
Climatic proofingDamp heat, constant,, to IEC 60068-2-78
Damp heat, cyclic. to IEC 60068-2-30
Ambient temperature-25 ° C / +70 ° C
Mounting positionAs required
Degree of protectionIP66. IP65 for “T” Type with rubber strain
Contacts / switching capacity
Rated impulse withstand voltageUimpVAC4000
Rated insulation voltageUiV400
Overvoltage category / pollution degreeIII/3
Rated operational current
AC – 1524 VIeA6
230 V / 240 VIeA6
400 V / 415 VIeA4
DC – 1324 VIeA10
110 VIeA1
220 VIeA0.5
Control circuit reliability
at 24V DC / 5mA HF Fault probability <10-7,<1 failure at 107 operations
at 5 V DC / 1mA HF Fault probability <10-6,<1 failure at 5×106 operations
Supply frequency Hz max. 400
Short-circuit rating in the closed state (IEC / EN 60947-5-1)
FuselessTypePKZM0-10 FAZ-B6/1
Max. FuselessA gG / gL10
Short-circuit rating to IEC / EN 60947-5-1
Max. FuselessA gG / gL6
Repetition accuracymm± 0.02
Mechanical variables
Lifespan
Standard-action contact Operations x106 8
Snap-action contact Operations x106 8
Contact temperature of roller head ° C ≤ 100
Mechanical shock resistance ( half-sinusoidal shock , 20ms )
Standard-action contact g 25
Snap-action contact g 2
Basic unit g
Operating frequency Operations/h ≤ 6000
Actuation
Mechanical
Actuating force at beginning/end of stroke
Basic units 8601 N 1.0 / 8.0
Basic units 8611 N 1.0 / 8.0
Basic units 8601 N 1.0 / 8.0
Basic units 8603 N 1.0 / 8.0
Actuating torque of rotary drives Nm 0.2
Max. operating speed with DIN cam
Basic units for angle of actuation 8601 a = 0 ° / 30 ° m/s 1 / 0.5
8604 for angle of actuation a = 0 ° m/s 1.5
8608 for angle of actuation a = 0 ° L = 125 mm m/s 1.5
8607 for angle of actuation L = 130 mm m/s 1.5
8602 for angle of actuation a = 30 ° / 45 ° m/s 1
8603 for angle of actuation a = 30 ° / 45 ° m/s 1
8611 for angle of actuation a = 0 ° / 30 ° m/s 1 / 1
Type No. M8 Series IP66 (With tail) Contact M = Make , B = Break , = Positive opening safety function to IEC/EN 60947-5-1 Circuit-Symbol Contact Sequence = Contact closed = Contact open ZW = Positive opening Sequence
8601A 1M 1B
8601AT
8601B 1M 1B
8601BT
8601C 2M –
8601CT
8601D – 2B
8601DT
8601E 1M 1B
8601ET
8611A 1M 1B
8611AT
8611E 1M1 1B
8611ET
8606E 1M 1B
8606ET
8602A 1M 1B
8602AT
8602B 1M 1B
8602BT
8602D – 2B
8602DT
8602E 1M 1B
8602ET
8603A 1M 1B
8603AT
8603B 1M 1B
8603BT
8603D – 2B
8603DT
8603E 1M1 1B
8603ET
8604A 1M 1B
8604AT
8604E 1M 1B
8604ET
8608A 1M 1B
8608AT
8608E 1M 1B
8608ET